sábado, 19 de octubre de 2019

Reliability of isometric and isokinetic trunk flexor strength using a functional electromechanical dynamometer


Compartimos una nueva e importante publicación de nuestros compañeros de la Red Pleokinetic de España y Chile. Este estudio, "Reliability of isometric and isokinetic trunk flexor strength using a functional electromechanical dynamometer", es parte de la tesis doctoral de la investigadora de la red Angela Rodríguez Perea de la Universidad de Granada (España). Destacamos que parte del trabajo se ha desarrollado durante el presente año en el Laboratorio de Evaluación del Movimiento Natural Controlado de la Universidad Católica de la Santísima Concepción en Concepción, Chile.




Reliability of isometric and isokinetic trunk flexor strength using a functional electromechanical dynamometer
Angela Rodriguez-Perea, Luis J. Chirosa Ríos, Dario Martinez-Garcia, David Ulloa-Díaz, Francisco Guede Rojas, Daniel Jerez-Mayorga, Ignacio J. Chirosa Rios

Aim: To determine the absolute and relative reliability of functional trunk tests, using a functional electromechanical dynamometer to evaluate the isokinetic strength of trunk flexors and to determine the most reliable assessment condition, in order to compare the absolute and relative reliability of mean force and peak force of trunk flexors and to determine which isokinetic condition of evaluation is best related to the maximum isometric. Methods: Test-retest of thirty-seven physically active male student volunteers who performed the different protocols, isometric contraction and the combination of three velocities (V1 = 015 m s−1 , V2 = 0.30 m s−1, V3 = 0.45 m s−1) and two range of movement (R1 = 25% cm ; R2 = 50% cm) protocols. Results: All protocols to evaluate trunk flexors showed an absolute reliability provided a stable repeatability for isometric and dynamic protocols with a coefficient of variation (CV) being below 10% and a high or very high relative reliability (0.69 < intraclass correlation coefficient [ICC] > 0.86). The more reliable strength manifestation (CV = 6.82%) to evaluate the concentric contraction of trunk flexors was mean force, with 0.15 m s−1 and short range of movement (V1R1) condition. The most reliable strength manifestation to evaluate the eccentric contraction of trunk flexors was peak force, with 0.15 m s−1 and a large range of movement (V1R2; CV = 5.07%), and the most reliable way to evaluate isometric trunk flexors was by peak force (CV = 7.72%). The mean force of eccentric trunk flexor strength with 0.45 m s−1 and short range of movement (V3R1) condition (r = 0.73) was best related to the maximum isometric contraction. Conclusion: Functional electromechanical dynamometry is a reliable evaluation system for assessment of trunk flexor strength.

No hay comentarios:

Publicar un comentario